Coronary stents
Coronary stents
ABLUMINAL COATINGFacilitate mono directional drug release and less systemicexposure of drug leading to faster re-endothelistation |
|
EDGE COATINGThe additional 0.5mm coating on the edge of the balloon which addresses the edge restenosis |
|||||
FUSION COATINGCoating on the stent and exposed parts of the balloon facilitate homogenous drug delivery which address diffused proliferative disease and focal restenosis |
BIODEGRADABLE FILMThe formation of circular film with biodegradable polymer facilitate maximum drug delivery in blood wet conditions |
Drug Polymer | |
Drug | Sirolimus |
Drug Dose | 1.40µg/mm² |
Drug Carrier | Customized biodegradable polymer matrix |
Stent | |
Stent Material | Cobalt Chromium Alloy L605 |
Strut Thickness | 73µm |
Strut Width | 80µm (hinge) – 120µm (strut) |
Average Recoil | Less than 5% |
Average Foreshortening | Less than 1% (Zero foreshortening design) |
Delivery System | |
Delivery System | RX stent delivery system |
Nominal Pressure | 8 bar |
Rated Burst Pressure | 14 bar |
Guide Wire Compatibility (max.) | 0.014″ |
Guiding Catheter Compatibility | 5F |
Stent Diameter (mm) | 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 |
Stent Length(mm) | 8, 12, 16, 20, 24, 28, 32, 36, 40 |
Crossing Profile | 0.038″ |
Entry Profile | 0.016″ |
Stent Diameter |
Stent Length | ||||||||
08 mm | 12 mm | 16 mm | 20 mm | 24 mm | 28 mm | 32 mm | 36 mm | 40 mm | |
2.25mm | EAN22508 | EAN22512 | EAN22516 | EAN22520 | EAN22524 | EAN22528 | EAN22532 | EAN22536 | EAN22540 |
2.50mm | EAN25008 | EAN25012 | EAN25016 | EAN25020 | EAN25024 | EAN25028 | EAN25032 | EAN25036 | EAN25040 |
2.75mm | EAN27508 | EAN27512 | EAN27516 | EAN27520 | EAN27524 | EAN27528 | EAN27532 | EAN27536 | EAN27540 |
3.00mm | EAN30008 | EAN30012 | EAN30016 | EAN30020 | EAN30024 | EAN30028 | EAN30032 | EAN30036 | EAN30040 |
3.50mm | EAN35008 | EAN35012 | EAN35016 | EAN35020 | EAN35024 | EAN35028 | EAN35032 | EAN35036 | EAN35040 |
4.00mm | EAN40008 | EAN40012 | EAN40016 | EAN40020 | EAN40024 | EAN40028 | EAN40032 | EAN40036 | EAN40040 |
CLINICAL EVIDENCE
PROB/DEFINITE STENT THROMBOSIS AT 1 YEAR
Product Specification
Stent Material: |
L605 CoCr |
Polymer: |
PLA, 100% Biodegradable |
Drug: |
Rapamycin (Sirolimus) |
Drug Dosage: |
0.3 µg/mm2 |
Strut Thickness: |
86µm (Ø2.25mm - 3.0mm) |
Nomial Pressure: |
10 atm |
Rated Burst Pressure: |
16 atm (Ø2.25mm - 3.5mm) |
Mean Recoil: |
3.4% |
Mean Foreshortening: |
1.95% - 5.30% |
Length /Ø |
8mm |
13mm |
16mm |
18mm |
21mm |
23mm |
26mm |
29mm |
31mm |
33mm |
35mm |
38mm |
2.25mm |
RV2208 |
RV2213 |
RV2216 |
RV2218 |
RV2221 |
RV2223 |
RV2226 |
RV2229 |
- |
- |
- |
- |
2.5mm |
RV2508 |
RV2513 |
RV2516 |
RV2518 |
RV2521 |
RV2523 |
RV2526 |
RV2529 |
RV2531 |
RV2533 |
- |
- |
2.75mm |
RV2708 |
RV2713 |
RV2716 |
RV2718 |
RV2721 |
RV2723 |
RV2726 |
RV2729 |
RV2731 |
RV2733 |
RV2735 |
RV2738 |
3.0mm |
RV3008 |
RV3013 |
RV3016 |
RV3018 |
RV3021 |
RV3023 |
RV3026 |
RV3029 |
RV3031 |
RV3033 |
RV3035 |
RV3038 |
3.5mm |
RV3508 |
RV3513 |
RV3516 |
RV3518 |
RV3521 |
RV3523 |
RV3526 |
RV3529 |
RV3531 |
RV3533 |
RV3535 |
RV3538 |
4.0mm |
RV4008 |
RV4013 |
RV4016 |
RV4018 |
RV4021 |
RV4023 |
RV4026 |
RV4029 |
RV4031 |
RV4033 |
RV4035 |
RV4038 |
Product Feature
Product Specification
Stent Material: | L605 CoCr |
Polymer: | PLA, 100% Biodegradable |
Drug: | Rapamycin (Sirolimus) |
Drug Density: | 0.3µg/mm2 |
Strut Thickness: |
86µm(Ø2.25mm-3.0mm) 96.5µm(Ø3.5mm-4.0mm) |
Nominal Pressure: | 10 atm |
Rated Burst Pressure: |
16atm(Ø2.25mm-3.5mm) 14atm(Ø4.0mm) |
Ordering Information
(mm)/Length (mm) | 8mm | 13mm | 16mm | 18mm | 21mm | 23mm | 26mm | 29mm | 31mm | 33mm | 35mm | 38mm |
2.25mm | RV2208 | RV2213 | RV2216 | RV2218 | RV2221 | RV2223 | RV2226 | RV2229 | - | - | - | - |
2.5mm | RV2508 | RV2513 | RV2516 | RV2518 | RV2521 | RV2523 | RV2526 | RV2529 | RV2531 | RV2533 | - | - |
2.75mm | RV2708 | RV2713 | RV2716 | RV2718 | RV2721 | RV2723 | RV2726 | RV2729 | RV2731 | RV2733 | RV2735 | RV2738 |
3.0mm | RV3008 | RV3013 | RV3016 | RV3018 | RV3021 | RV3023 | RV3026 | RV3029 | RV3031 | RV3033 | RV3035 | RV3038 |
3.5mm | RV3508 | RV3513 | RV3516 | RV3518 | RV3521 | RV3523 | RV3526 | RV3529 | RV3531 | RV3533 | RV3535 | RV3538 |
4.0mm | RV4008 | RV4013 | RV4016 | RV4018 | RV4021 | RV4023 | RV4026 | RV4029 | RV4031 | RV4033 | RV4035 | RV4038 |
PRODUCT FEATURE
CLINICAL EVIDENCE
Proven Safety and Efficacy in All Complexity
Product Specification
Material: |
L605 CoCr Alloy |
Stent Design: |
Open-cell with S Link |
Strut Thickness: |
86µm |
Crossing Profile: |
0.039” |
Drug: |
Sirolimus (Rapamycin) |
Drug Dosage: |
9µg/mm |
Polymer: |
SIBS |
Ordering Information
Diameter (mm)/Length (mm) |
13mm |
16mm |
18mm |
21mm |
23mm |
26mm |
29mm |
31mm |
33mm |
2.50mm |
G2513 |
G2516 |
G2518 |
G2521 |
G2523 |
G2526 |
G2529 |
G2531 |
G2533 |
2.75mm |
G 2713 |
G2716 |
G2718 |
G2721 |
G2723 |
G2726 |
G2729 |
G2731 |
G2733 |
3.00mm |
G 3013 |
G3016 |
G3018 |
G3021 |
G3023 |
G3026 |
G3029 |
G3031 |
G3033 |
3.50mm |
G3513 |
G3516 |
G3518 |
G3521 |
G3523 |
G3526 |
G3529 |
G3531 |
G3533 |
4.00mm |
G4013 |
G4016 |
G4018 |
G4021 |
G4023 |
G4026 |
G4029 |
G4031 |
G4033 |